For Sports and Event Venues

Home-field advantage for every venue.

Noda works as a virtual building engineer across stadiums, arenas, and convention centers, cutting energy costs whether a venue is sold out or empty.

Implement dynamic CW resetNeeds Acceptance$71,940/yr
$372K
Annual savings at Globe Life Field since 2021
$113K
A year from re-sequencing the chillers at the same ballpark
$61K
Implemented energy savings at one NFL stadium

Lower operating costs, season after season.

Noda finds savings in the central plants and air handlers serving seating bowls, concourses, suites, and exhibit halls, through busy schedules and the quiet stretches in between.

Run central plants at optimal efficiency.

Venue chiller plants are sized for a full house on the hottest day of the year, and most of the time they run well below that load. Noda's AI agents find setpoints that waste energy at part load, such as cooling tower fans held at full speed, and write up each fix as a Project ready to accept.

Explore the Intelligence Layer
Insight
Cooling Tower Relief Optimization Opportunity
CW Plant · Merriton Park · Approach 3.6°F
Condenser water setpoint72°FFixed
  • CT-1Fan speed100%
  • CT-2Fan speed100%
  • CT-3Fan speed98%
  • CT-4Fan speed97%

Stop conditioning empty concourses and halls.

Most venues sit empty on far more days than they host events, yet air handlers serving concourses, suites, and exhibit halls often keep event-day schedules. Noda checks each unit against its occupancy schedule and flags units that run while their spaces sit empty.

Explore the platform
Insights 4All venues
  • Fan Commanded On 24/7AHU-C2 · Merriton Park, main concourseHigh
  • AHU In Occupied Mode While Scheduled UnoccupiedAHU-S4 · Larkhaven Arena, suite levelHigh
  • Fan on while AHU UnoccupiedAHU-X1 · Larkhaven Convention Center, Hall BMedium
  • Optimum start opportunityAHU-L1 · Merriton Park, club loungeLow

Trace comfort complaints to their cause.

When a concourse runs warm mid-event, engineers can ask the Noda Assistant why. It reasons over the venue's trend data, equipment relationships, and open Insights, and links each conclusion to the data behind it.

Explore the Noda Assistant
Noda Assistant Larkhaven Arena
Why did the north concourse run warm during Saturday's event?

AHU-N3 held its 55°F discharge setpoint until 8:40 PM, then drifted to 61°F with its chilled water valve fully open.

CH-2 shut down at 8:36 PM, and CH-1 carried the plant alone for the rest of the event, so chilled water supply rose with the load.

Open CH-2 status trend
Ask a question…

Report measured savings season by season.

Noda measures each completed Project against a weather-adjusted baseline, so venue leadership and sustainability partners see what each season's changes saved in dollars, energy, and emissions.

See Noda for sustainability teams
Closed ProjectsMerriton Park
Portfolio ViewBuilding View
Realized Savings$284,610
GHG Emissions Reduced742,380kgCO2e
Energy Saved2,318,460kWh
Projects Completed14
  • Johnson Controls
  • Honeywell
  • Siemens
  • Trane
  • Schneider Electric
  • Automated Logic
  • Distech Controls
  • Delta Controls
  • Tridium
  • Alerton

Works with the systems you already use.

Noda reads each venue's BMS over BACnet/IP, Modbus, or MQTT through the Noda LaunchPad, a secure on‑premises gateway that collects data around the clock.

The infield at Globe Life Field during a game, with full stands under the closed roof
Globe Life Field
Case study
“The partnership with Noda is a reflection of Globe Life Field’s emphasis on energy efficiency. We are thrilled to be among the early adopters of their technology and continue to reap the rewards from using their solution. We look forward to more utility cost savings.”
Sean Decker
SVP Operations and Events · Globe Life Field
4.5M
kWh saved annually since 2021
1.8M
kg CO2e avoided annually
7.25%
Gain in overall plant efficiency

Plant and air-side results from Noda customers

Sports & entertainmentCentral plantEnergy savings

$256,000 in annual savings from a 32% jump in plant efficiency.

What Noda Diagnosed

A new MLB stadium — with the largest single-panel retractable roof in the world — ran its condenser water plant at a fixed supply temperature, forcing chillers into low-efficiency operation with cooling tower fans pegged at 100%. A dynamic CWST reset tied to outside air conditions dropped plant efficiency from 0.91 to 0.59 kW/ton, a 32% gain.

3.2M kWh reduced over the season
0.91 → 0.59 kW/ton
32% efficiency gain
Dynamic CWST reset

Related reading

Frequently asked questions

  • Does Noda help venues that sit empty most of the year?

    Yes. Between events, Noda checks air handlers and plant equipment against each space's occupancy schedule and flags units running for empty spaces.

  • How do Noda's recommendations fit around the event calendar?

    Noda's recommendations go to the venue's engineering team, and the team decides which to accept and when to make each change.

  • Does Noda work for convention centers and exhibition halls?

    Yes. Exhibit halls, meeting rooms, and ballrooms sit in the same model as seating bowls and concourses, and Noda analyzes the air handlers and plant serving each.

  • Does Noda work with retractable-roof and open-air stadiums?

    Yes. Noda analyzes the central plant and air handlers whatever the venue's design, including at an MLB ballpark with a retractable roof.

AI that never sits out a game.

Continuous analysis for every venue, in season and off.

Get a demo