ENERGY STAR Portfolio Manager: A Complete Guide

Published Oct 30, 2026

ENERGY STAR Portfolio Manager: A Complete Guide

In short

ENERGY STAR Portfolio Manager is the free online benchmarking tool of the US ENERGY STAR program. Building owners enter metered or billed energy, water, and waste data, and the tool calculates energy use intensity, greenhouse gas emissions, and, for eligible property types, a 1–100 ENERGY STAR score comparing the building with similar buildings nationwide.

Nearly a quarter of US commercial building space is benchmarked in Portfolio Manager, according to ENERGY STAR. EPA launched the tool in 1999, according to the Portfolio Manager introduction to web services, and since then it has become the reference format for building energy data in the United States. Benchmarking ordinances are written around Portfolio Manager, building performance standards set their targets in its metrics, and the ENERGY STAR score appears in leasing materials, loan documents, and sustainability reports.

Portfolio Manager is a measurement tool: it records what buildings consumed, converts that consumption into comparable metrics, and ranks the result against national peers. The accuracy of every metric depends on the data entered, and none of the metrics explains why buildings perform as they do.

How does Portfolio Manager work?

Portfolio Manager builds each property record from a description of the property and a set of meters, then calculates its metrics from the consumption logged against those meters.

Property details: The property type, gross floor area, and use details that drive energy demand. For an office these include weekly operating hours, number of workers, number of computers, and the share of floor area that is heated and cooled. Mixed-use properties are entered as several property uses within one property, each with its own floor area and details.

Meters: One record for each energy source the building buys or produces, such as grid electricity, natural gas, district steam, district chilled water, and fuel oil, along with optional water and waste meters. Each meter holds a series of consumption entries, typically monthly, taken from utility bills or interval data.

Data reaches those records through the following methods, according to the ENERGY STAR overview of Portfolio Manager:

  • Manual entry through the web interface
  • Single-meter spreadsheet upload, pasted from Excel
  • Multi-meter spreadsheet templates for larger portfolios
  • Portfolio Manager web services, an interface that lets utilities and approved software providers exchange data with Portfolio Manager accounts automatically

Account holders can share a property with other users at full or limited access, so a property manager, an owner, a consultant, and a city benchmarking office can all work from the same record. An owner can also send data requests to collect information from tenants or managers in a structured format.

Metrics Portfolio Manager calculates

Portfolio Manager reports hundreds of metrics, and the following carry the most weight with benchmarking laws, certification programs, and investors.

Metric Measures Typical use
Site energy use intensity (EUI) Annual energy recorded at the meters, per square foot Tracking one building over time
Source EUI Site energy plus generation and delivery losses, per square foot Comparing buildings with different fuel mixes
Weather-normalized EUI Site or source EUI adjusted to a long-term average climate Year-over-year comparison that removes weather effects
ENERGY STAR score Percentile ranking against similar buildings nationwide, 1–100 Certification, leasing, some performance standards
Greenhouse gas emissions Direct, indirect, and total emissions, in metric tons of CO2e Carbon disclosure and emissions-based standards
Water use intensity Water use per square foot Water benchmarking ordinances
Waste and diversion rate Waste generated and share diverted from landfill Sustainability reporting

Why does Portfolio Manager use source energy?

Portfolio Manager uses source energy because it puts buildings with different fuel mixes on equal terms. The Portfolio Manager technical reference on source energy calls it "the most equitable unit of evaluation". A building heated by an onsite gas boiler and an otherwise identical building heated by electric resistance record very different site energy, because the electricity arrives after the power plant has already lost most of the fuel's energy as heat. Source energy adds those production, transmission, and delivery losses back in, expressing every fuel as the raw energy consumed to deliver that fuel.

The conversion uses a single national source-site ratio for each fuel: 2.80 for grid electricity and 1.05 for natural gas, both last revised in August 2018, according to the same technical reference. Because the ratios are national, no building gains or loses points because of its local utility's generation mix.

Site energy remains useful for managing a single building: it matches the utility bill and tracks operational changes month to month. Portfolio Manager reports both, and ENERGY STAR's explanation of the difference recommends source energy for comparisons between buildings.

How is the ENERGY STAR score calculated?

The ENERGY STAR score ranks a building's energy performance against similar buildings across the country, on a scale where 50 is the median and 75 marks the top quartile. The method, set out in the ENERGY STAR score technical reference, works through the following steps.

  1. Actual source EUI: Portfolio Manager converts twelve full calendar months of metered or billed consumption, for every fuel, into source energy and divides the total by floor area.
  2. Predicted source EUI: A regression model predicts the source EUI of a typical building with the same property type, operating hours, occupancy, equipment, and climate. Each property type has its own model, built with weighted ordinary least squares on national survey data.
  3. Efficiency ratio: Actual source EUI is divided by predicted source EUI. A ratio below one means the building uses less energy than its prediction.
  4. Percentile lookup: ENERGY STAR fits a gamma distribution to the efficiency ratios of the buildings in the national survey and converts the curve into a lookup table. The building's ratio maps to a score from 1 to 100.

The national survey behind most models is the Commercial Buildings Energy Consumption Survey (CBECS), conducted by the US Energy Information Administration, which samples more than 5,000 buildings, according to the technical reference. Where CBECS data is insufficient for a property type, ENERGY STAR uses other datasets: the hospital score, for example, draws on 2015 survey data from the American Society for Health Care Engineering, according to ENERGY STAR's record of score updates.

The score compares a building with the national building stock as surveyed, rather than with other Portfolio Manager users, so a score of 75 means better than three quarters of the country's comparable buildings. Because the regression already accounts for operating hours, workers, and climate, buildings cannot raise their scores by running longer hours or adding staff. Scores move when buildings use less energy for the same work.

Which property types can earn an ENERGY STAR score?

Only property types with a statistically sound national reference model can receive a score. The eligible list includes offices, K-12 schools, hotels, hospitals, retail stores, supermarkets, warehouses, multifamily housing, senior living communities, worship facilities, bank branches, courthouses, residence halls, and data centers, among others. ENERGY STAR maintains the full eligibility list. In the US, K-12 schools, multifamily housing, hospitals, hotels, and senior living communities made up of several co-located buildings serving one function earn certification as a campus, according to the Portfolio Manager glossary.

Properties outside the list still benchmark every other metric. Laboratories, many industrial facilities, and mixed-use properties dominated by an unscored use receive EUI, emissions, and water metrics without a score. Several benchmarking ordinances account for this by setting requirements in EUI or emissions intensity, which apply to every property type.

How does weather normalization work?

Portfolio Manager handles weather in two separate places: inside the ENERGY STAR score, and in a weather-normalized EUI reported for each building.

Inside the score, the regression models include heating degree days and cooling degree days, calculated against a 65°F base, as variables. A building in Minneapolis is compared with what a similar building in the Minneapolis climate would be expected to use, and the score technical reference reports that humidity and average temperature add no significant explanatory power once degree days are included.

The weather-normalized EUI works on the building's own history. Portfolio Manager regresses the building's monthly consumption against the degree days recorded at its assigned weather station, then estimates what the building would have used under average climate conditions. For US buildings, those averages are the National Oceanic and Atmospheric Administration's climate normals, and the most recent set covers 2006 to 2020, according to the Portfolio Manager technical reference on climate and weather. Managers comparing buildings with their own previous years should use weather-normalized EUI, because a mild winter can lower raw EUI with no operational change at all.

How does a building earn ENERGY STAR certification?

ENERGY STAR certification recognizes buildings that score 75 or higher, confirmed by a licensed professional. ENERGY STAR's application instructions and the Licensed Professional's Guide set the following requirements.

Score: 75 or higher, based on twelve consecutive months of measured data for all fuels.

Timing: The owner must submit the application within 120 days of the period ending date. From January 2026, a building that receives certification must wait 11 months before applying for its next certification of either type, according to ENERGY STAR.

Verification: A Professional Engineer or Registered Architect licensed in any US state or territory, or in Canada, visits the building while it is occupied and operating normally, verifies floor area, use details, and energy data, and signs and stamps the application.

Indoor environment: The licensed professional confirms that the building meets ANSI/ASHRAE Standard 62.1 for outdoor air ventilation, ANSI/ASHRAE Standard 55 for thermal comfort, and the IES Lighting Handbook for illumination. The criteria prevent buildings from earning high scores by under-ventilating or under-lighting their spaces.

Certification covers one year of performance, and buildings reapply annually. ENERGY STAR estimates verification for an average building at around $1,500. The 11-month rule changes how a certified portfolio schedules its applications, as ENERGY STAR recertification deadlines in 2026 sets out.

Standard certification and NextGen

ENERGY STAR NextGen is an optional higher tier for US commercial and multifamily buildings that adds emissions and renewable energy criteria to the standard requirements.

Requirement ENERGY STAR certification ENERGY STAR NextGen
ENERGY STAR score 75 or higher 75 or higher
Onsite emissions No requirement Direct greenhouse gas intensity at or below a property-specific target
Renewable energy No requirement At least 30 percent of total energy, or 100 percent of electricity if lower
Licensed professional verification Required Required
Recertification Annual Annual

Which laws require Portfolio Manager?

As of 2024, more than three dozen US benchmarking laws required covered buildings to report through Portfolio Manager, according to ENERGY STAR. They include New York City's Local Law 84, Boston's Building Emissions Reduction and Disclosure Ordinance (BERDO), and Washington DC's benchmarking program. Covered owners typically submit annually by sharing their Portfolio Manager property with the jurisdiction or generating a jurisdiction-specific report from the property record.

Building performance standards go further, setting minimum performance that buildings must reach over time, and several express those targets in Portfolio Manager metrics. Washington DC's Building Energy Performance Standards, for example, set each threshold no lower than the local median ENERGY STAR score for the property type, or an equivalent metric. DC BEPS Cycle 1: What Building Owners Can Still Change Before December 31 covers the practical consequences. Other standards use site EUI, source EUI, or emissions intensity, each calculated in Portfolio Manager from the same consumption data.

The global guide to building energy regulations maps the benchmarking and performance laws in force, with dates and thresholds for each, and the 2026 regulatory roundup summarizes the year's changes.

Is ENERGY STAR still running?

Yes. As of 2026, ENERGY STAR and Portfolio Manager continue to operate, with the Department of Energy replacing the EPA as lead agency.

In May 2025 the administration proposed eliminating the EPA office that runs ENERGY STAR. Congress instead mandated at least $33 million for ENERGY STAR in fiscal year 2026, which the US Green Building Council described as the first time Congress had set a mandatory annual spending level for the program. On March 3, 2026, the EPA and the Department of Energy signed a memorandum of agreement making DOE the lead federal agency for ENERGY STAR.

The transition plan, finalized on August 28, 2026, organizes the move into workstreams for knowledge transfer and consolidation of program leadership at DOE, legal transfer of the ENERGY STAR trademark and partnership agreements, and migration of the program's IT systems and data. The plan targets moving Portfolio Manager, the energystar.gov website, and the program's data assets to DOE hosting before July 2027, and gives DOE access to the existing systems to run program processes before the migration completes. The plan aims for minimal disruption to stakeholders and does not announce changes to the score, certification, or reporting workflows.

ENERGY STAR is funded through annual appropriations. The fiscal year 2026 law, P.L. 119-74, directed EPA to spend not less than $33,024,000 on the program, according to the Congressional Research Service, and funding for later years depends on each year's appropriations. The program also has fewer staff assigned to it than before the 2025 cuts, with losses in leadership and across the team, NPR reported in February 2026.

The transition plan also records that EPA has not worked on updating specifications, a term the plan applies to the ENERGY STAR score, since early 2025, and that outstanding issues pass to DOE for review. A future update to the score models is therefore possible. What Happened to ENERGY STAR covers the steps portfolio managers can take during the transition, including keeping an exported copy of their benchmarking history.

Data quality in Portfolio Manager

A Portfolio Manager record is only as accurate as the data entered, and the most common errors come from routine data collection.

Missing meters: A tenant-paid electricity account, a backup generator's fuel, or a district steam connection left out of the record understates consumption and can inflate the score. New York City's Local Law 84, for example, requires owners to report the consumption of the entire building, including tenant consumption.

Floor area errors: Gross floor area is the denominator of every intensity metric. A figure taken from a leasing schedule often measures rentable area instead, and the error shifts every intensity metric by the same proportion.

Gaps and estimates: A month missing from any meter prevents a score, and estimated bills carried forward without a true-up distort the twelve-month total.

Stale use details: Operating hours, occupancy, and computer counts entered once at setup and never revised skew the prediction behind the score.

Lag: Monthly utility bills arrive weeks after the consumption they record. Building managers reviewing Portfolio Manager see performance from one to two months earlier, which is adequate for annual compliance and too late to catch equipment that started wasting energy this week.

Utilities that deliver aggregated whole-building data through web services close the tenant-meter gap in multi-tenant buildings. 3 Reasons Your Utility Bills Are Inaccurate covers billing errors in more detail.

Scope and limits of a benchmark

Portfolio Manager reports how buildings performed and how that performance compares with their peers. It cannot report which equipment caused the result, because its inputs are whole-building totals measured monthly. A score of 62 places a building ahead of 62 percent of its national peers and gives no indication of the cause of the gap to the top quartile: a chiller plant sequencing poorly, air handlers running outside occupied hours, or simultaneous heating and cooling across a floor.

Owners raise a score through work done outside Portfolio Manager. Operational changes alone can reduce energy use substantially: a Pacific Northwest National Laboratory study estimated that 34 control measures, led by setpoint adjustment, reduced minimum airflow, and occupancy-based scheduling, could cut energy use across US commercial buildings by about 29 percent. The conditions those measures correct include setpoints that have drifted, schedules that no longer match occupancy, overrides left in place, and control sequences that fight each other. Engineers find those conditions in equipment-level data from the building management system, through periodic retro-commissioning or continuous fault detection and diagnostics. Agentic AI for building operations covers software that carries those findings through to completed changes.

Operational fixes reach the benchmark through the meters: consumption avoided this month lowers the twelve-month total behind the next score.

Where Noda fits

Noda is an agentic AI platform for commercial building operations that works as an always-on virtual building engineer, scaling engineering team capacity across every asset in a portfolio.

Portfolio Manager measures the annual energy performance of buildings from utility and meter totals, and its metrics show performance moving without identifying the equipment or operating changes that moved it. Noda works on the day-to-day operations that drive energy use.

Each site connects through a Noda LaunchPad, an on-premise gateway that reads the building management system over open protocols such as BACnet/IP and Modbus. Noda analyzes BMS trend data, meter data, and weather continuously, traces faults to their root causes, and tests each finding against historical data before raising it. Each confirmed issue becomes a proposed change to a setpoint, schedule, or control sequence, with the evidence and an estimate of the annual savings, for an engineer to accept or decline. Changes of this kind typically cost little or nothing to make.

Noda tracks the savings each completed change returns, and the lower consumption carries through to the next Portfolio Manager submission, in source EUI, in the ENERGY STAR score, and in the metrics that benchmarking laws and building performance standards set. The Intelligence Layer page describes the approach in more detail.

See it in your buildings

A demo shows how Noda finds the operational changes that move a building's energy performance, each carrying its estimated savings.

Request a demo

Frequently asked questions

  • Is ENERGY STAR Portfolio Manager free to use?

    Yes. Creating an account, adding properties, and benchmarking them in Portfolio Manager carries no fee. The costs sit around the tool: staff time or software to collect utility data, and, for buildings applying for ENERGY STAR certification, a licensed professional's verification, which ENERGY STAR puts at around $1,500 for an average building.

  • Is Portfolio Manager still running in 2026?

    Yes. Congress provided at least $33 million for ENERGY STAR in fiscal year 2026, and a March 3, 2026 memorandum of agreement made the Department of Energy the program's lead agency. The transition plan finalized on August 28, 2026 targets moving Portfolio Manager to DOE hosting before July 2027, and the tool continues to operate through the transfer.

  • How is the ENERGY STAR score calculated?

    Portfolio Manager compares a building's actual source energy use intensity with the source energy use intensity predicted for a similar building with the same operating characteristics and climate. The prediction comes from a regression model built on national survey data, chiefly the Commercial Buildings Energy Consumption Survey. The ratio of actual to predicted energy is converted into a percentile from 1 to 100.

  • Is a score of 50 good?

    A score of 50 represents median energy performance: the building performs better than half of comparable buildings nationwide and worse than the other half. Scores of 75 and above place a building in the top quartile and make it eligible to apply for ENERGY STAR certification.

  • Which buildings can receive an ENERGY STAR score?

    Only property types for which ENERGY STAR has a statistically valid national reference model, including offices, K-12 schools, hotels, hospitals, retail stores, supermarkets, warehouses, multifamily housing, worship facilities, and data centers. ENERGY STAR maintains the full eligibility list. Properties outside the list can still benchmark every other metric in Portfolio Manager.

  • How much data does a building need for an ENERGY STAR score?

    Twelve full calendar months of data for every energy type the building uses, together with property use details such as gross floor area, operating hours, and number of workers. A missing meter or a gap in any month of the record prevents Portfolio Manager from calculating a score.

  • Why does Portfolio Manager use source energy instead of site energy?

    Site energy is what the meters record. Source energy adds the losses incurred producing and delivering that energy, so a kilowatt-hour of grid electricity and a therm of natural gas are expressed in comparable units of raw fuel. ENERGY STAR applies one national source-site ratio per fuel, 2.80 for grid electricity and 1.05 for natural gas, so no building is credited or penalized for its utility's generation mix.

  • Does the ENERGY STAR score account for weather?

    Yes. The regression models include heating and cooling degree days, so a building in a cold or hot climate is compared against what a similar building in the same conditions would be expected to use. Portfolio Manager also reports a separate weather-normalized energy use intensity, which adjusts a building's consumption to average climate conditions for year-over-year comparison. For US buildings, the averages are the National Oceanic and Atmospheric Administration's climate normals for 2006 to 2020.

  • Can an ENERGY STAR score change without any change to the building?

    Yes. Scores move when ENERGY STAR updates its reference models with newer national survey data or revises its source-site ratios. The August 2018 update refreshed scores for US buildings across all time periods and moved offices, hotels, K-12 schools, retail stores, supermarkets, warehouses, and worship facilities onto models built on 2012 survey data. Certification for those types was suspended during a review and resumed on a rolling basis, for every type by July 2019.

  • How does a building qualify for ENERGY STAR certification?

    A building needs an ENERGY STAR score of 75 or higher, based on twelve months of measured data, with the application submitted within 120 days of the period ending date. A licensed Professional Engineer or Registered Architect must visit the building, verify the floor area, use details, and energy data, confirm indoor environment criteria for ventilation, thermal comfort, and lighting, and sign and stamp the application.

  • How often does a building need to recertify?

    Certification covers one year of performance, and buildings reapply annually with new data and a new verification. From January 2026, a building that receives certification must wait 11 months before applying for its next certification of either type, standard or NextGen.

  • How does ENERGY STAR NextGen differ from standard certification?

    NextGen adds two requirements to the standard criteria: onsite greenhouse gas emissions intensity at or below a property-specific target, and at least 30 percent of total energy from eligible renewable sources, or 100 percent of electricity if that is lower. A NextGen building must still score 75 or higher and pass the same professional verification.

  • Do building energy laws require Portfolio Manager?

    Many do. As of 2024, ENERGY STAR counted more than three dozen US benchmarking laws that require covered buildings to report through Portfolio Manager, including New York City's Local Law 84, Boston's BERDO, and Washington DC's benchmarking program. Several building performance standards also set their compliance targets in Portfolio Manager metrics such as energy use intensity or the ENERGY STAR score.

  • How do utilities send data to Portfolio Manager?

    Through Portfolio Manager web services, an application programming interface that lets approved utilities and software providers exchange data with Portfolio Manager accounts. Some utilities use web services to deliver aggregated whole-building consumption, which removes the need to collect a bill from every tenant in a multi-tenant building.

  • Can I export my data from Portfolio Manager?

    Yes. The Reporting tab produces custom reports covering properties, meters, scores, and historical metrics, downloadable as spreadsheets. Keeping an annual export of the full benchmarking history in an internal system is sensible practice, independent of any change to the program.

  • Does a high ENERGY STAR score mean a building is running efficiently?

    A high score means the building used less energy over the past twelve months than most comparable buildings. The score is annual, whole-building, and retrospective, so it cannot show which equipment is wasting energy today. Buildings can score well while chillers run overnight or schedule overrides stay in place, and the extra consumption shows up in their scores only as it accumulates in the twelve-month total.