Class A operations for every office.

Noda's AI agents give every building a senior engineer's attention around the clock. They trace faults to their root causes, hold down peak demand, and rank each fix by what it saves.

Repair CHW bypass valveNeeds Acceptance$18,600/yr
$166K
Annual savings at one Class A office tower
15–25%
Typical energy savings
300M
Sq ft under Noda analysis, across leading global portfolios

More savings. Happier tenants.

Noda lowers energy spend, demand charges, and reactive repair costs across portfolios, regardless of a building's age, systems, or BMS. Its AI agents catch equipment problems early, before they turn into comfort issues.

Problems become Projects automatically.

Engineering teams start each day from a short list of fixes worth making, with the triage and root cause analysis already done by Noda's AI agents.

Explore the Intelligence Layer
Root Cause Analyzer
CH-2Reverse Flow in Chiller BypassCHW Delta T 5.8°F
Repair CHW bypass valve
AHU-2Unable to provide cooling to space
VAV-12High space temperature
VAV-14High space temperature

Reduce demand, not comfort.

Cut peak demand charges with no one on call during the event. Automated Demand Management raises zone cooling setpoints a little at a time as power nears the limit, never past each zone's maximum.

Explore Automated Demand Management
Building powerAbove the demand limit
812 kW
Limit 800 kW
VAV-12-3Floor 12 east74°FMax 77°F
VAV-12-7Floor 12 west73°FMax 76°F
VAV-9-2Floor 9 east74°FMax 76°F
VAV-6-5Floor 6 lobby72°FMax 74°F

Answers on demand for every engineer.

Any engineer at any building can diagnose a unit by asking. The Noda Assistant answers from trend data, such as why a chiller draws more power than its load predicts.

Explore the Noda Assistant
Noda Assistant The Cromwell Building
Why is CH-1 using more power at The Cromwell Building?

CH-1 is drawing more power than predicted at its current load, and the gap has widened over six weeks.

Condenser approach temperature has risen alongside it, which points to fouled condenser tubes.

Open CH-1 power trend
Ask a question…

One set of priorities across the portfolio.

Site and portfolio teams work the highest-value fixes first. Command Center gathers Projects from every building into one worklist, ranked by priority and then by estimated savings.

Explore Command Center
HomeMy ViewTeam View
Top Projects to Accept$22,900
  • AHU-3Return AHU-3 to schedule4400 Lexington Tower · Sam A$3,300/yrAccept
  • CH-2Optimize CH-2 stagingOne Northstar Place · Craig N$9,600/yrNudge
  • VAV-22Retune VAV-22 valve loopThe Cromwell Building · Gus P$2,900/yrNudge
  • AHU-7Replace AHU-7 actuator1850 Sequoia Center · Craig N$4,200/yrNudge
Projects to be Verified$13,200
Tasks to Start
Tasks to Complete
  • Johnson Controls
  • Honeywell
  • Siemens
  • Trane
  • Schneider Electric
  • Automated Logic
  • Distech Controls
  • Delta Controls
  • Tridium
  • Alerton

Works with the systems you already use.

Noda connects to leading building management systems and to anything supporting BACnet/IP, Modbus, or MQTT, through the Noda LaunchPad, a secure on‑premises gateway.

Results with real impact

Class A officeChiller plantOpEx reduction

$166,000 in annual savings by rerouting tenant loads off a 24/7 chiller plant.

What Noda Diagnosed

A landmark DC office tower ran two chillers 24/7 to serve tenant supplemental loads, even though overnight activity was minimal. Migrating those tenant systems to the retail condenser loop let the main chiller shut down 9 PM–6 AM, cutting ~20,000 kWh weekly year-round.

~20K kWh reduced weekly
Chiller off 9 PM–6 AM
Sustained year-round
Zero comfort impact

Related reading

Frequently asked questions

  • Will tenants notice a difference in comfort?

    Each Project names the change to make and the equipment it affects, and an engineer reviews it before accepting. Noda's fault detection keeps running on the same equipment and zones after the work is done, so a zone that drifts from setpoint appears as a new Insight. During a demand event, ADM raises cooling setpoints only on enrolled zones, never past the maximum set for each zone, and returns each setpoint to BMS control when the event ends.

  • How does Noda handle tenant after-hours requests?

    Each building's schedule in Noda carries working hours, holidays, startup and shutdown times, and tenant requests. Charts shade those schedule events behind the trends, so an engineer can tell an approved after-hours request from equipment left running by mistake.

  • Our buildings run different building management systems. Does that matter?

    No. Noda connects to leading BMS vendors and to open protocols through the Noda LaunchPad, and the Independent Data Layer maps every building's points onto one normalized model of its equipment and the zones each unit serves.

  • Do we need new hardware or sensors?

    Noda reads the data each BMS already trends through the Noda LaunchPad, a secure gateway installed on site. Deployment adds no new controls hardware and requires no BMS reprogramming.

  • How are savings measured?

    Noda measures each completed Project against a counterfactual baseline normalized for weather and occupancy, and reports the measured result as the Project's savings.

AI that never goes out of office.

24/7 analysis for every building you run.